Abstract: This application note helps system designers properly select the external components used with the MAX16946 remote antenna regulator and current-sense amplifier (CSA) to ensure that the automotive antenna detection subsystem meets the target requirements. An electronic calculator is provided to help calculate the parameters of the MAX16946 external key components. The calculator is also used to determine the device's operating range and analog output voltage accuracy.
introduction
The MAX16946 is a high-voltage regulator with a high-precision current-sense amplifier (CSA) designed to provide the hidden power supply for remote antennas in automobiles. The device provides short-circuit protection, current limit protection and open load detection. The current limit of current limit protection and open load protection can be set by external resistors. To ensure that the antenna detection circuit meets the target requirements, the engineer must correctly select external components.
Figure 1 shows the typical application of MAX16946. The main external components and their functions are as follows:
RSENSE is a resistor, through which the load current is detected, and CSA measures and amplifies the voltage across the resistor. Therefore, the sense resistor is very important to determine the overall system accuracy.
R5 and R6 set the regulator output voltage.
The external capacitance of COMP ensures the stability of the regulator under any operating conditions.
R1 and R2 set the current threshold during the fault condition. If the current is maintained at the current threshold for the shielding time of 100ms (minimum), the output is turned off, triggering / SC output low level, retry after 1100ms.
R3 and R4 set the open load detection threshold, when the load current is lower than this threshold, trigger / OL output low level.
When the output is turned off and LOUT attempts to maintain current, the Schottky diode DOUT provides transient negative voltage protection for the MAX16946 OUT pin. Without this diode, OUT may be -0.3V below its absolute maximum voltage, which is not allowed.
Figure 1. Typical operating circuit of the MAX16946 remote antenna CSA and switch
When using CSA and switches for antennas, designers must usually determine the range of working load, normal operating conditions, short circuit and current limit (Figure 2). In addition, the accuracy of the CSA analog output voltage must be verified.
Figure 2. Operating range of the current-sense amplifier
Use the MAX16946 calculator to determine the correct current-sense resistor and resistor divider. These resistor values ​​are used to set the current limit and open load threshold. The calculator considers the tolerance of external components and the MAX16946. By calculating the tolerance range of each design parameter, the designer can ensure that the design parameters are within the range specified by the system specifications.
High Voltage Laboratory Power Supplies
The LTP series laboratory high-voltage power supply is a high-voltage power supply specially designed for high-voltage laboratory applications with high precision, high stability, and low ripple output characteristics. Built in 19 inches, 2U standard chassis with designed output power at 1KW and output voltage ranges 1KV to 60KV.
After optimizing the output stability and output ripple on the basis of the 1KW high-voltage power module, the stability and ripple of the high voltage lab power supplies can reach the level at 0.1%.
The high-voltage laboratory power supply is also a constant-voltage and constant-current type high-voltage power supply. The output voltage and current can be continuously adjusted from 0 to the rated value via the added control potentiometers added to the front panel, high resolution LEDs display for output KV and mA are also added for intuitive measuring of high voltage laboratory bench.
The lab high voltage power supply is also equipped with DB9 interface as standard. Customers can apply 0-10V signals and dry contact signals to the interface according to our interface definition to achieve comprehensive control and monitoring functions on the power supply, like high voltage start / stop, output setting and reading.
The LTP series laboratory high voltage power supply is equipped with complete protection functions, which can deal with sparking, short circuit, overload, load discharge and other situations.
At present, the high-voltage laboratory power supply is mainly used in Laboratory power, High-voltage test stands, Electrostatics, Capacitor / Insulations testing and Electrophoresis applications.
High Voltage Lab Power Supplies, High Voltage Laboratory Power Supplies, High-voltage Lab Power Supplies, Laboratory High Voltage Power Supplies, Lab High Voltage Power Supplies