Construction
Conductor:
THHN: stranded, uncoated copper conductors per ASTM-B3, ASTM-B787
and ASTM-B8
• MTW: bare, annealed copper per ASTM-B3, -B8 and -B787
Insulation:
Color coded polyvinyl chloride (PVC), heat, moisture and flame retardant compound
per UL 83 and UL 1063.
Covering:
A tough abrasion resistant polyamide (Nylon) covering.
Specifications
THHN / THWN-2 or MTW meets or exceeds all applicable ASTM specifications
UL 83: Thermoplastic-Insulated Wires and Cables
UL 1063: Machine-Tool Wires and Cables (stranded cables only)
NEMA WC70 / ICEA S-95-658: Power Cables Rated 2000V or Less for the Distribution of Electrical Energy
Federal Specification A-A-59544 and requirements of the NEC
CSA C22.2 No. 75-03Â Thermoplastic Insulated Wires and Cables
Ratings
VW-1 rated 14 AWG - 1 AWG
1/0 AWG and larger is rated for CT (cable tray) use.
6 AWG and larger is rated for sunlight resistance in all colors. All sizes are rated "gasoline and oil resistant II."
Â





Construction
Conductor:
THHN: stranded, uncoated copper conductors per ASTM-B3, ASTM-B787
and ASTM-B8
• MTW: bare, annealed copper per ASTM-B3, -B8 and -B787
Insulation:
Color coded polyvinyl chloride (PVC), heat, moisture and flame retardant compound
per UL 83 and UL 1063.
Covering:
A tough abrasion resistant polyamide (Nylon) covering.
Specifications
THHN / THWN-2 or MTW meets or exceeds all applicable ASTM specifications
UL 83: Thermoplastic-Insulated Wires and Cables
UL 1063: Machine-Tool Wires and Cables (stranded cables only)
NEMA WC70 / ICEA S-95-658: Power Cables Rated 2000V or Less for the Distribution of Electrical Energy
Federal Specification A-A-59544 and requirements of the NEC
CSA C22.2 No. 75-03Â Thermoplastic Insulated Wires and Cables
Ratings
VW-1 rated 14 AWG - 1 AWG
1/0 AWG and larger is rated for CT (cable tray) use.
6 AWG and larger is rated for sunlight resistance in all colors. All sizes are rated "gasoline and oil resistant II."
Â





With Push-in connection technology, you can connect conductors easily – both directly and without tools, insert forces reduced by 50%. it is suitable for various applications. Insert rigid conductors or conductors with ferrules from 0.25mm² into the conductor shaft.The contact spring opens automatically and provides the required pressure force against the current bar.
When installing smaller conductors from 0.14mm², use a standard screwdriver to push the orange button and actuate the contact spring.
Push-in Connection have test and passed various certificates. For example, Vibration resistance in accordance with railway standard DINEN50155,shock and corrosion resistance in accordance with current shipbuilding registers.
Insulated Quick Connector,Quick Splice Connector,Push In Wire Connectors,Splicing Connector With Levers